To make the required connection to the EZS unit, follow these steps:
-
Use the CB0602 Cable from the ZN081 set , to connect it to the EZS socket
-
Connect the CB602 Cable to the ZN081 CAN Gateway connector “B”.
-
Insert the 5A fuse into the dedicated socket
-
Connect the DC jack of the 24V power supply unit
-
Connect the AVDI Interface with the help of CB601 cable to the “A” connector of the CAN Gateway