The meaning of the check-boxes is as follows:
-
CAN TP2.0 – when trying to connect to the device the Diagnostics will try to connect to it using “KWP2000 over TP2.0 with baud 500KB/s”
-
CAN TP1.6 – when trying to connect to the device the software will try to connect to it using “KWP2000 over TP1.6 with baud 500KB/s”
-
UDS - when trying to connect to the device the software will try to connect to it using “UDS over ISO transport protocol” with baud 500KB/s
-
K-Line KWP2000/KWP1281 - when trying to connect to the device the software will try to connect to it using “KWP1281 or KWP2000 over K-Line”
NOTE: These check boxes are used only for configuring the used protocols when trying to connect to the device in order to perform standard diagnostic requests. They are not applicable when auto-scanning devices.