Once all the connections (described below) are done, you can open the FBS4 Manager > select the DSM > read the module.

Original DSM needs to be connected and you need to open the DSM selection of the FBS4 manager, and press the “ Save ” button. This would read the required data from the DSM and let you save it to a file located on your computer.

Next step is to connect the donor DSM and read the unit (by pressing “info”) and check if everything is in tact. FBS4 Manager > DSM Selection. After that you can proceed with making the unit virgin by pressing the “ Virgin ” button.

You would now have to press “ Personalize “ button, which would ask you to upload the file, previously saved from the original DSM. Once done, you can press the “info” button and check if the unit is personalized and activated. If everything is good, you would only have to do one more thing.

Last step to complete the procedure is to write the VIN of the vehicle into the unit by pressing the “ VIN “ button, and a pop-up window will appear where you need to write the correct VIN to the unit.