WIKI

Vehicle coverage: Toyota, Lexus and Scion instrument clusters with RH850 processors.


Required equipment

Connection

For vehicles equipped with dashboard units with an RH850 processor you will need to connect both:

  1. To the OBDII port of the vehicle, and
  2. To the internal CAN bus of the vehicle, using CB012 or CB031.

Unlike the S6J3 clusters, the internal CAN connection here is not optional — it is needed regardless of the gateway type.


Procedure

The procedure is identical to the one described for S6J3 clusters — you can read, write and restore. For the details of each operation, refer to Dashboard Calibration for Instrument Clusters with S6J3 Processors.

Operation What it does
Read Reads the dashboard and displays the current mileage; a backup is created automatically.
Write Re-reads the unit, creates a backup, then writes the new odometer value into the instrument panel.
Restore Writes back a previously saved backup file, chosen from the list the software displays.

Important notes


Troubleshooting

Issue Likely cause Solution
No communication with the cluster Internal CAN not connected RH850 clusters need CB012/CB031 in addition to OBDII
Read fails partway Unstable connection or power Re-seat the CAN connection, connect a charger, and retry
Unsure which backup to restore Several backups present Match the processor type and creation timestamp in the file name