Key Learning (Mechanical Key)
Designed for automotive locksmiths and workshops, the Abrites solution for key programming in All Keys Lost (AKL) situations is a world-first, straightforward solution via OBD. Using the AVDI and ZN067 cable, the process is user-friendly and fully guided.
- No expensive vehicle module replacements required
- No need to remove, disassemble, or open the immobilizer module
Supported operations: both All Keys Lost and spare key programming.
(If a working key is available, an alternative approach may be to clone the transponder.)
Coverage applies regardless of market: US, European, UK, and Asian versions are all supported. No connection to Toyota servers or any third-party tools is required.
Required equipment
- Abrites AVDI interface
- Abrites OBDII cable – CB106
- Toyota mechanical key (H-type) adapter set – ZN069, which includes:
- ZN067 adapter – allows direct connection to the fuses required for the bladed key programming procedures;
- ZN068 emulator – Used for vehiles manufactured before 2018 to emulate a master key;
Supported models
All Toyota vehicles using a mechanical/bladed H-type key, 128-bit DST-AES (8A), model years up to 2027:
Example of models using mechanical key:
- Tacoma
- Tundra
- 4Runner
- Sienna
- Yaris
- Prius
- Camry
- Corolla
- RAV4
- Highlander
- Sequoia
- Hilux
- Land Cruiser 70 series
- Land Cruiser Prado (lower trims)
- HiAce
- Fortuner
- Rush
- Avanza
- and others
Step‑by‑step procedure
The procedure can be performed via OBDII or through a bench connection using the immobiliser module. For the bench setup, see Bench connection.
1. Start Key Programming
Select Learn Keys in the software.

2. Begin the procedure
Press and hold the START button to begin.
3. Locate the immobilizer fuses
Using the wiring diagram for the particular vehicle, find the fuses (or connector) that supply the immobilizer unit:
| Signal | Description | Typical rating | ZN067 cable |
|---|---|---|---|
| B+ (+B) | Permanent B+ to the immobilizer unit | 5 A or 7.5 A | Yellow |
| IG SW | Provides B+ to the immobilizer unit only with the key in the ignition ON position | 10 A or 20 A | Orange |
| KEY SW | Key-in switch (if present); the cable goes to the connector on the side of the key barrel | – | White cable |
4. Check the live data
Open the immobilizer module in diagnostics and select LIVE DATA. The values +B, IG SW and KEY SW should all read NORMAL / ON.

5. Identify the correct fuses
Pull the fuses one at a time and wait a few seconds:
- If nothing changes, put the fuse back and try the next one.
- When a value changes from positive (for example ON) to negative (for example OFF), that is the correct fuse.
The correct fuses are almost always the same size as the ones on the ZN067 and usually between 10 A and 20 A, so there is no need to check larger fuses.
Fuse location examples
Some vehicles have more than one fuse for B+ and/or IGN. If there is more than one candidate, always start with the fuse with the lowest amperage. For example, if there are two B+ fuses, one 15 A and one 5 A, try the 5 A fuse first.
Example: IGN fuse in the engine compartment fuse box

Example: B+ fuse in the cabin fuse box

6. Connect the ZN067
Connect the ZN067 between the AVDI and the CB106.
7. Connect the cables
- Yellow cable → B+
- Orange cable → IG SW
- Smaller cable → KEY-in SW
For KEY-in SW you do not need to find a fuse. Disconnect the connector going into the ignition switch and plug the ZN067 cable in its place. This may require removing some plastic trim.
8. Continue with the guided steps
Follow the on-screen instructions to complete the key learning.
Within the procedure, you need to program all keys, including both the old and the new ones. Any key that is not presented during the procedure will be deactivated, but it can be added again at a later point via the same procedure
9. ECU synchronisation
Once the key programming stage is complete, proceed with synchronizing the ECU (hybrid ECU) so that the new keys are synchronized within the immobilizer system.
Plase refer to - ECU synchronisation
10. Remote control registration
The last step is to program the remotes. Use the dedicated menu to synchronize the remote control functionality of the newly added keys.

Bench connection
Use this setup when the the vehicle is not availabe.
The module is powered by an external 12V supply, and the ZN067 adapter provides the connection to the module.
Additional requirements
- External 12V power supply (not included in the ZN069 set)
- ZN067 adapter (included in the ZN069 set)

Connection
- Connect the wires from the module connector to the ZN067, as shown in the picture. The enlarged view shows the connector pins in use.
- Connect the external 12V power supply to the ZN067.
- Connect the ZN067 to the AVDI.
- Switch on the power supply, then continue with the guided steps in the software, starting from Step 1 then junp to Step 8 and follow the procedure to the end.
| Wire colour (in picture) | Module connector pin |
|---|---|
| Yellow | pin 11 |
| White | pin 10 |
| Grey | pin 3 |
| Green | pin 6 |
| Brown | pin 9 |
!!! Important
- Check the connector orientation and pin positions before you apply power.
- Make sure the power supply is set to 12V before you connect it.
- Do not disconnect the wires or the power while the software is reading or writing.
Important notes
- Follow the on-screen order exactly.
- Always use the vehicle wiring diagram to identify the immobilizer fuses.
- Check the +B, IG SW and KEY SW values in LIVE DATA after connecting the cables to confirm the correct fuses are replced.
- With several fuses for the same signal, try the lower-amperage one first.
- Only work on vehicles you own or are authorized to service.
- Once the mechanical key programming procedure has been performed with the Abrites software, the official Toyota tester tool (Techstream) can no longer be used to add spare keys.
Troubleshooting
| Issue | Likely cause | Solution |
|---|---|---|
| Live data values do not change when a fuse is pulled | Wrong fuse | Put the fuse back and try the next one, starting with the lowest amperage |
| Several fuses for B+ or IGN | Duplicate circuits on the vehicle | Try the lowest-amperage fuse first |
| No KEY SW reading | KEY SW cable not connected | Disconnect the ignition switch connector and plug the ZN067 while cable in the proper place |